Тестирование: виртуальный ups¶
конфиг - /etc/nut/ups.conf
[apc] driver = dummy-ups port = evolution500.dev desc = "dummy-ups in dummy mode"
файл-состояния ups(примерное содержимое ответа dell) - /etc/nut/evolution500.dev
battery.capacity: 9.00 battery.charge: 100 battery.charge.low: 30 battery.charge.restart: 0 battery.energysave: no battery.runtime: 23148 battery.runtime.low: 180 battery.type: PbAc device.mfr: DELL device.model: Dell UPS Rack/Tower 2700W HV - 230V device.serial: CN-0J727N-75162-9BA-0093-A00 device.type: ups driver.name: usbhid-ups driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.version: 2.6.4 driver.version.data: MGE HID 1.31 driver.version.internal: 0.37 input.frequency: 49.9 input.frequency.nominal: 50 input.transfer.boost.low: 210 input.transfer.high: 286 input.transfer.low: 160 input.transfer.trim.high: 250 input.voltage: 212.0 input.voltage.nominal: 230 outlet.1.autoswitch.charge.low: 0 outlet.1.delay.shutdown: 2147483647 outlet.1.delay.start: 0 outlet.1.desc: PowerShare Outlet 1 outlet.1.id: 1 outlet.1.status: on outlet.1.switchable: yes outlet.2.autoswitch.charge.low: 0 outlet.2.delay.shutdown: 2147483647 outlet.2.delay.start: 1 outlet.2.desc: PowerShare Outlet 2 outlet.2.id: 2 outlet.2.status: on outlet.2.switchable: yes outlet.desc: Main Outlet outlet.id: 0 outlet.switchable: no output.current: 0.80 output.frequency: 49.9 output.frequency.nominal: 50 output.voltage: 247.0 output.voltage.nominal: 230 ups.beeper.status: enabled ups.date: 2011/08/02 ups.delay.shutdown: 20 ups.delay.start: 30 ups.firmware: 01.04.0001 ups.load: 7 ups.load.high: 110 ups.mfr: DELL ups.model: Dell UPS Rack/Tower 2700W HV - 230V ups.power: 198 ups.power.nominal: 2700 ups.productid: ffff ups.realpower: 141 ups.realpower.nominal: 2700 ups.serial: CN-0J727N-75162-9BA-0093-A00 ups.start.battery: yes ups.start.reboot: yes ups.status: OL CHRG BOOST ups.test.interval: 7776000 ups.test.result: No test initiated ups.time: 16:45:33 ups.timer.shutdown: 0 ups.timer.start: 0 ups.type: offline / line interactive ups.vendorid: 047c
возможные значения ups.status
OL - On line (mains is present) OB - On battery (mains is not present) LB - Low battery HB - High battery RB - The battery needs to be replaced CHRG - The battery is charging DISCHRG - The battery is discharging (inverter is providing load power) BYPASS - UPS bypass circuit is active - no battery protection is available CAL - UPS is currently performing runtime calibration (on battery) OFF - UPS is offline and is not supplying power to the load OVER - UPS is overloaded TRIM - UPS is trimming incoming voltage (called "buck" in some hardware) BOOST - UPS is boosting incoming voltage FSD - Forced Shutdown (restricted use, see the note below)
Обновлено Константин Пильник около 8 лет назад · 2 изменени(я, ий)