Разобрать RAID¶
hpacucli controller slot=0 logicaldrive 1 delete Warning: Deleting an array can cause other array letters to become renamed. E.g. Deleting array A from arrays A,B,C will result in two remaining arrays A,B ... not B,C Warning: Deleting the specified device(s) will result in data being lost. Continue? (y/n) y [451078.420172] hpsa 0000:04:00.0: Direct-Access device c0b0t0l1 removed. [451078.423421] hpsa 0000:04:00.0: didn't find c0b0t0l1 for removal.
Собрать RAID¶
hpacucli ctrl slot=0 create type=ld drives=2I:1:7,2I:1:8 raid=1 Warning: Creation of this logical drive has caused array letters to become renamed. [451635.869049] hpsa 0000:04:00.0: Direct-Access device c0b0t0l1 added. [451635.875684] scsi 0:0:0:1: Direct-Access HP LOGICAL VOLUME 6.00 PQ: 0 ANSI: 5 [451635.879234] sd 0:0:0:1: Attached scsi generic sg1 type 0 [451635.882803] sd 0:0:0:1: [sda] 976707632 512-byte logical blocks: (500 GB/465 GiB) [451635.886746] sd 0:0:0:1: [sda] Write Protect is off [451635.890341] sd 0:0:0:1: [sda] Mode Sense: 6b 00 00 08 [451635.890675] sd 0:0:0:1: [sda] Write cache: disabled, read cache: disabled, doesn't support DPO or FUA [451635.906377] sda: unknown partition table [451635.910956] sd 0:0:0:1: [sda] Attached SCSI disk
Добавить spare drive¶
hpacucli controller slot=0 array A add spares=2I:1:5 hpacucli controller all show config Smart Array P410i in Slot 0 (Embedded) (sn: 50123456789ABCDE) array A (SATA, Unused Space: 0 MB) logicaldrive 1 (465.7 GB, RAID 1, OK) physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SATA, 500 GB, OK) physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SATA, 500 GB, OK) physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SATA, 500 GB, OK, spare) array B (SAS, Unused Space: 0 MB) logicaldrive 2 (273.4 GB, RAID 1+0, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 146 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 146 GB, OK)
Обновлено Андрей Волков больше 9 лет назад · 5 изменени(я, ий)