LSI-Logic MPT-Fusion » История » Редакция 2
Редакция 1 (Андрей Волков, 2015-03-13 12:50) → Редакция 2/11 (Андрей Волков, 2015-03-13 12:57)
h1. LSI-Logic MPT-Fusion h2. LSI-Logic-SAS1064E-B3-SAS3042E h3. Смотрим *./sasflash -listall* <pre> **************************************************************************** LSI Corporation SAS FLASH Utility. SASFlash Version 1.30.00.00 (2011.08.24) Copyright (c) 2006-2011 LSI Corporation. All rights reserved. **************************************************************************** Adapter Selected is a LSI SAS 1064E(B3): Num Ctlr FW Ver NVDATA x86-BIOS EFI-BSD PCI Addr ----------------------------------------------------------------------- 1 1064E(B3) 01.23.39.00 2b.86 06.18.05.00 No Image 00:09:00:00 Finished Processing Commands Successfully. Exiting SASFlash. </pre> *lsiutil -p 1 -i -s* <pre> LSI Logic MPT Configuration Utility, Version 1.62, January 14, 2009 1 MPT Port found ============================================================================== /proc/mpt/ioc0 LSI Logic SAS1064E B3 MPT 105 Firmware 01172700 IOC 0 Seg/Bus/Dev/Fun Board Name Board Assembly Board Tracer 0 9 0 0 SAS3042E L3-25006-02C P62200BGKW540H Current Port State ------------------ SAS1064E's links are 1.5 G, 1.5 G, down, down Software Version Information ---------------------------- Current active firmware version is 01172700 (1.23.39) Firmware image's version is MPTFW-01.23.39.00-IE LSI Logic x86 BIOS image's version is MPTBIOS-6.18.05.00 (2008.05.14) Firmware Settings ----------------- SAS WWID: 500605b000144f2c Multi-pathing: Disabled SATA Native Command Queuing: Disabled SATA Write Caching: Disabled SATA Maximum Queue Depth: 1 Device Missing Report Delay: 3 seconds Device Missing I/O Delay: 3 seconds Phy Parameters for Phynum: 0 1 2 3 Link Enabled: Yes Yes Yes Yes Link Min Rate: 1.5 1.5 1.5 1.5 Link Max Rate: 3.0 3.0 3.0 3.0 SSP Initiator Enabled: Yes Yes Yes Yes SSP Target Enabled: No No No No Port Configuration: Auto Auto Auto Auto Target IDs per enclosure: 1 Persistent mapping: Enabled Physical mapping type: Enclosure/Slot Target ID 0 reserved for boot: Yes Starting slot (direct attach): 1 Target IDs (physical mapping): 8 Interrupt Coalescing: Enabled, timeout is 16 us, depth is 4 Persistent Mappings ------------------- No persistent entries found B___T___L Type Vendor Product Rev SASAddress PhyNum 0 1 0 Disk ATA OCZ-AGILITY3 2.25 1221000000000000 0 0 2 0 Disk ATA OCZ-AGILITY3 2.25 1221000001000000 1 </pre> h3. Перепрошиваем Firmware *./sasflash -fwall 6ei_r_ld.fw* <pre> **************************************************************************** LSI Corporation SAS FLASH Utility. SASFlash Version 1.30.00.00 (2011.08.24) Copyright (c) 2006-2011 LSI Corporation. All rights reserved. **************************************************************************** Ignoring All other commands except for output flags Attempting to flash firmware to LSI SAS 1064E(B3): Executing Operation: Flash Firmware Image Checksum Passed: 00000000 Verifying NVDATA Compatibility. . . NVDATA Versions Compatible Product ID and Vendor ID match verified. Valid BootLoader Image verified. Beginning Firmware Download Firmware Download: SUCCESSFUL! Verifying the image flashed correctly. . . Firmware Flash: SUCCESSFUL! Resetting Adapter: Adapter Successfully reset. Updating VPD data! VPD update not needed Finished Processing Commands Successfully. Exiting SASFlash. </pre> h3. Смотрим <pre> ./sasflash -listall **************************************************************************** LSI Corporation SAS FLASH Utility. SASFlash Version 1.30.00.00 (2011.08.24) Copyright (c) 2006-2011 LSI Corporation. All rights reserved. **************************************************************************** Adapter Selected is a LSI SAS 1064E(B3): Num Ctlr FW Ver NVDATA x86-BIOS EFI-BSD PCI Addr ----------------------------------------------------------------------- 1 1064E(B3) 01.23.46.00 2b.90 06.18.05.00 No Image 00:09:00:00 Finished Processing Commands Successfully. Exiting SASFlash. </pre> h3. Перепрошиваем BIOS <pre> </pre>