Действия
Recovery-raid-megaraid » История » Редакция 1
Редакция 1/3
| Следующее »
Рамиль Абдулбяров, 2015-04-29 17:55
Восстановление массива¶
Скидываем конфигурацию с диска:¶
megacli -CfgForeign -Clear -a0
Foreign configuration 0 is cleared on controller 0. Exit Code: 0x00
Смотрим, что изменилось:¶
megacli pdinfo -PhysDrv \[32:16\] -a0 nolog
1 2 Enclosure Device ID: 32 3 Slot Number: 16 4 Enclosure position: 1 5 Device Id: 16 6 WWN: 5000C50071CAF938 7 Sequence Number: 1 8 Media Error Count: 0 9 Other Error Count: 0 10 Predictive Failure Count: 0 11 Last Predictive Failure Event Seq Number: 0 12 PD Type: SAS 13 14 Raw Size: 279.396 GB [0x22ecb25c Sectors] 15 Non Coerced Size: 278.896 GB [0x22dcb25c Sectors] 16 Coerced Size: 278.875 GB [0x22dc0000 Sectors] 17 Sector Size: 0 18 Firmware state: Unconfigured(good), Spun Up 19 Device Firmware Level: YS0A 20 Shield Counter: 0 21 Successful diagnostics completion on : N/A 22 SAS Address(0): 0x5000c50071caf939 23 SAS Address(1): 0x0 24 Connected Port Number: 0(path0) 25 Inquiry Data: SEAGATE ST9300653SS YS0A6XN62C41 26 FDE Capable: Not Capable 27 FDE Enable: Disable 28 Secured: Unsecured 29 Locked: Unlocked 30 Needs EKM Attention: No 31-Foreign State: Foreign 32-Foreign Secure: Drive is not secured by a foreign lock key 33+Foreign State: None 34 Device Speed: 6.0Gb/s 35 Link Speed: 6.0Gb/s 36 Media Type: Hard Disk Device 37 Drive Temperature :30C (86.00 F) 38 PI Eligibility: No 39 Drive is formatted for PI information: No 40 PI: No PI 41 Port-0 : 42 Port status: Active 43 Port's Linkspeed: 6.0Gb/s 44 Port-1 : 45 Port status: Active 46 Port's Linkspeed: Unknown 47 Drive has flagged a S.M.A.R.T alert : No 48 49 Exit Code: 0x00
Обновлено Рамиль Абдулбяров больше 9 лет назад · 3 изменени(я, ий)