HPSA » История » Версия 5
Константин Пильник, 2020-02-26 10:07
| 1 | 1 | Андрей Волков | h1. HPSA |
|---|---|---|---|
| 2 | |||
| 3 | 2 | Константин Пильник | h2. Показать конфигурацию контроллера |
| 4 | |||
| 5 | <pre> |
||
| 6 | hpacucli ctrl slot=4 show config detail |
||
| 7 | </pre> |
||
| 8 | |||
| 9 | h2. Показать физические диски |
||
| 10 | |||
| 11 | <pre> |
||
| 12 | hpacucli ctrl slot=4 pd all show status |
||
| 13 | </pre> |
||
| 14 | |||
| 15 | h2. Просмотр информации о конкретном диске |
||
| 16 | |||
| 17 | <pre> |
||
| 18 | hpacucli ctrl slot=4 physicaldrive 1I:1:1 show |
||
| 19 | </pre> |
||
| 20 | |||
| 21 | h2. Показать логические диски |
||
| 22 | |||
| 23 | <pre> |
||
| 24 | hpacucli ctrl slot=4 ld all show |
||
| 25 | </pre> |
||
| 26 | |||
| 27 | h2. Информация о логическом диске |
||
| 28 | |||
| 29 | <pre> |
||
| 30 | hpacucli ctrl slot=4 logicaldrive 1 show |
||
| 31 | </pre> |
||
| 32 | |||
| 33 | h2. Включить диод на диске |
||
| 34 | |||
| 35 | <pre> |
||
| 36 | hpacucli ctrl slot=1 pd 1I:1:1 modify led=on |
||
| 37 | </pre> |
||
| 38 | |||
| 39 | h2. Выключить диод на диске |
||
| 40 | |||
| 41 | <pre> |
||
| 42 | hpacucli ctrl slot=1 pd 1I:1:1 modify led=off |
||
| 43 | </pre> |
||
| 44 | |||
| 45 | 1 | Андрей Волков | h2. Разобрать RAID |
| 46 | |||
| 47 | <pre> |
||
| 48 | hpacucli controller slot=0 logicaldrive 1 delete |
||
| 49 | |||
| 50 | Warning: Deleting an array can cause other array letters to become renamed. |
||
| 51 | E.g. Deleting array A from arrays A,B,C will result in two remaining |
||
| 52 | arrays A,B ... not B,C |
||
| 53 | |||
| 54 | |||
| 55 | Warning: Deleting the specified device(s) will result in data being lost. |
||
| 56 | Continue? (y/n) y |
||
| 57 | |||
| 58 | [451078.420172] hpsa 0000:04:00.0: Direct-Access device c0b0t0l1 removed. |
||
| 59 | [451078.423421] hpsa 0000:04:00.0: didn't find c0b0t0l1 for removal. |
||
| 60 | </pre> |
||
| 61 | |||
| 62 | h2. Собрать RAID |
||
| 63 | 2 | Константин Пильник | |
| 64 | 3 | Константин Пильник | h3. raid10 |
| 65 | |||
| 66 | 2 | Константин Пильник | <pre> |
| 67 | hpacucli ctrl slot=4 create type=ld drives=1I:1:1,1I:1:2,1I:1:3,1I:1:4 raid=1+0 stripesize=256 |
||
| 68 | </pre> |
||
| 69 | 3 | Константин Пильник | |
| 70 | h3. raid1 |
||
| 71 | 1 | Андрей Волков | |
| 72 | <pre> |
||
| 73 | hpacucli ctrl slot=0 create type=ld drives=2I:1:7,2I:1:8 raid=1 |
||
| 74 | |||
| 75 | Warning: Creation of this logical drive has caused array letters to become |
||
| 76 | renamed. |
||
| 77 | |||
| 78 | [451635.869049] hpsa 0000:04:00.0: Direct-Access device c0b0t0l1 added. |
||
| 79 | [451635.875684] scsi 0:0:0:1: Direct-Access HP LOGICAL VOLUME 6.00 PQ: 0 ANSI: 5 |
||
| 80 | [451635.879234] sd 0:0:0:1: Attached scsi generic sg1 type 0 |
||
| 81 | [451635.882803] sd 0:0:0:1: [sda] 976707632 512-byte logical blocks: (500 GB/465 GiB) |
||
| 82 | [451635.886746] sd 0:0:0:1: [sda] Write Protect is off |
||
| 83 | [451635.890341] sd 0:0:0:1: [sda] Mode Sense: 6b 00 00 08 |
||
| 84 | [451635.890675] sd 0:0:0:1: [sda] Write cache: disabled, read cache: disabled, doesn't support DPO or FUA |
||
| 85 | [451635.906377] sda: unknown partition table |
||
| 86 | [451635.910956] sd 0:0:0:1: [sda] Attached SCSI disk |
||
| 87 | </pre> |
||
| 88 | |||
| 89 | h2. Добавить spare drive |
||
| 90 | |||
| 91 | <pre> |
||
| 92 | hpacucli controller slot=0 array A add spares=2I:1:5 |
||
| 93 | |||
| 94 | hpacucli controller all show config |
||
| 95 | |||
| 96 | |||
| 97 | Smart Array P410i in Slot 0 (Embedded) (sn: 50123456789ABCDE) |
||
| 98 | |||
| 99 | array A (SATA, Unused Space: 0 MB) |
||
| 100 | |||
| 101 | |||
| 102 | logicaldrive 1 (465.7 GB, RAID 1, OK) |
||
| 103 | |||
| 104 | physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SATA, 500 GB, OK) |
||
| 105 | physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SATA, 500 GB, OK) |
||
| 106 | physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SATA, 500 GB, OK, spare) |
||
| 107 | |||
| 108 | array B (SAS, Unused Space: 0 MB) |
||
| 109 | |||
| 110 | |||
| 111 | logicaldrive 2 (273.4 GB, RAID 1+0, OK) |
||
| 112 | |||
| 113 | physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) |
||
| 114 | physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) |
||
| 115 | physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 146 GB, OK) |
||
| 116 | physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 146 GB, OK) |
||
| 117 | </pre> |
||
| 118 | 4 | Константин Пильник | |
| 119 | h2. Конвертация RAID 10 в RAID 6 |
||
| 120 | |||
| 121 | <pre> |
||
| 122 | hpacucli ctrl slot=2 ld 1 modify raid=6 |
||
| 123 | 5 | Константин Пильник | |
| 124 | # Расширяем полученный RAID до максимального размера: |
||
| 125 | |||