Проект

Общее

Профиль

Действия

LSI-Logic MPT-Fusion » История » Редакция 3

« Предыдущее | Редакция 3/11 (Разница(diff)) | Следующее »
Андрей Волков, 2015-03-13 12:59


LSI-Logic MPT-Fusion

LSI-Logic-SAS1064E-B3-SAS3042E

Смотрим

./sasflash -listall

 ****************************************************************************
    LSI Corporation SAS FLASH Utility.

    SASFlash Version 1.30.00.00 (2011.08.24) 

    Copyright (c) 2006-2011 LSI Corporation. All rights reserved.
 ****************************************************************************

    Adapter Selected is a LSI SAS 1064E(B3):

 Num   Ctlr      FW Ver     NVDATA   x86-BIOS     EFI-BSD    PCI Addr
-----------------------------------------------------------------------

1   1064E(B3)  01.23.39.00  2b.86  06.18.05.00    No Image   00:09:00:00

Finished Processing Commands Successfully.
    Exiting SASFlash.

lsiutil -p 1 -i -s

LSI Logic MPT Configuration Utility, Version 1.62, January 14, 2009

1 MPT Port found

==============================================================================

/proc/mpt/ioc0    LSI Logic SAS1064E B3    MPT 105   Firmware 01172700   IOC 0

Seg/Bus/Dev/Fun    Board Name       Board Assembly   Board Tracer
 0   9   0   0     SAS3042E         L3-25006-02C     P62200BGKW540H  

Current Port State
------------------
SAS1064E's links are 1.5 G, 1.5 G, down, down

Software Version Information
----------------------------
Current active firmware version is 01172700 (1.23.39)
Firmware image's version is MPTFW-01.23.39.00-IE
  LSI Logic
x86 BIOS image's version is MPTBIOS-6.18.05.00 (2008.05.14)

Firmware Settings
-----------------
SAS WWID:                       500605b000144f2c
Multi-pathing:                  Disabled
SATA Native Command Queuing:    Disabled
SATA Write Caching:             Disabled
SATA Maximum Queue Depth:       1
Device Missing Report Delay:    3 seconds
Device Missing I/O Delay:       3 seconds
Phy Parameters for Phynum:      0    1    2    3    
  Link Enabled:                 Yes  Yes  Yes  Yes  
  Link Min Rate:                1.5  1.5  1.5  1.5  
  Link Max Rate:                3.0  3.0  3.0  3.0  
  SSP Initiator Enabled:        Yes  Yes  Yes  Yes  
  SSP Target Enabled:           No   No   No   No   
  Port Configuration:           Auto Auto Auto Auto 
Target IDs per enclosure:       1
Persistent mapping:             Enabled
Physical mapping type:          Enclosure/Slot
Target ID 0 reserved for boot:  Yes
Starting slot (direct attach):  1
Target IDs (physical mapping):  8
Interrupt Coalescing:           Enabled, timeout is 16 us, depth is 4

Persistent Mappings
-------------------
No persistent entries found

 B___T___L  Type       Vendor   Product          Rev      SASAddress     PhyNum
 0   1   0  Disk       ATA      OCZ-AGILITY3     2.25  1221000000000000     0
 0   2   0  Disk       ATA      OCZ-AGILITY3     2.25  1221000001000000     1

Перепрошиваем Firmware

./sasflash -fwall 6ei_r_ld.fw

 ****************************************************************************
    LSI Corporation SAS FLASH Utility.

    SASFlash Version 1.30.00.00 (2011.08.24) 

    Copyright (c) 2006-2011 LSI Corporation. All rights reserved.
 ****************************************************************************

    Ignoring All other commands except for output flags

    Attempting to flash firmware to LSI SAS 1064E(B3):

    Executing Operation: Flash Firmware Image

        Checksum Passed: 00000000

        Verifying NVDATA Compatibility. . .
        NVDATA Versions Compatible

        Product ID and Vendor ID match verified.

        Valid BootLoader Image verified.

        Beginning Firmware Download
        Firmware Download: SUCCESSFUL!

        Verifying the image flashed correctly. . . 

        Firmware Flash: SUCCESSFUL!

        Resetting Adapter:
        Adapter Successfully reset.

        Updating VPD data!
        VPD update not needed

Finished Processing Commands Successfully.
    Exiting SASFlash.

Смотрим

./sasflash -listall

  ****************************************************************************
     LSI Corporation SAS FLASH Utility.

     SASFlash Version 1.30.00.00 (2011.08.24) 

     Copyright (c) 2006-2011 LSI Corporation. All rights reserved.
  ****************************************************************************

     Adapter Selected is a LSI SAS 1064E(B3):

  Num   Ctlr      FW Ver     NVDATA   x86-BIOS     EFI-BSD    PCI Addr
 -----------------------------------------------------------------------

-1   1064E(B3)  01.23.39.00  2b.86  06.18.05.00    No Image   00:09:00:00
+1   1064E(B3)  01.23.46.00  2b.90  06.18.05.00    No Image   00:09:00:00

 Finished Processing Commands Successfully.
     Exiting SASFlash.

Перепрошиваем BIOS


Обновлено Андрей Волков почти 10 года назад · 11 изменени(я, ий)